D 200:4L

D 200:4L

993,000.00

Out of stock

20,000 Watt Amplifier with 4 Flexible Output Channels, LAKE Digital Signal Processing and Digital Audio Networking for Installation Applications

  • 20,000 Watt amplifier with 4 flexible output channels and up to 5,900 Watts channel output
  • LAKE digital signal processing for unparalleled loudspeaker management and system control
  • Integrated 8×8 channels of dual redundant Dante* digital audio networking with AES67 support
  • 4 x 4,400 Watts into 2 Ohms, 4 x 5,000 Watts into 2.67 Ohms, 4 x 4,400 Watts into 4 Ohms, 4 x 2,300 Watts into 8 Ohms, 4 x 1,150 Watts into 16 Ohms, 4 x 3,300 Watts into Hi-Z 70 V, 4 x 4,700 Watts into Hi-Z 100 V
  • Proven and reliable Class-TD output stage with proprietary Intercooler high-efficiency cooling system
  • Rational Power Management (RPM) provides total flexibility to allocate available power across all 4 output channels
  • Best-in-class Power Factor Correction (PFC) with Current Draw Modelling reduces running costs and minimizes environmental impact
  • Under-Voltage Limiting (UVL) for continued operation during severe mains supply voltage drops
  • Dedicated on-board surveillance and load monitoring for mass notification applications
  • Redundant audio inputs and on-board system surveillance for voice alarm systems
  • CAFÉ (Configuring Amplifiers For the Environment) software for design, system planning, equipment planning, installation and commissioning
  • Control and monitoring integration with 3rd-party matrix systems including MediaMatrix* and Q-Sys* via dedicated interfacing software
  • Dedicated front-panel mute buttons for each amplifier channel with bicolour LED indication
  • 4 “LAKE Class” analog input channels with Iso-Float ground isolation for reliable audio distribution
  • 4 input channels of AES/EBU (AES3) digital audio supporting all standard sample rates up to 192 kHz with 24-bit resolution
  • 2 Neutrik etherCON* RJ-45 ports provide dual redundant Dante interfaces and remote configuration via LAKE Controller and Dante Controller software
  • Balanced analog and digital audio inputs and amplifier outputs on plug-in Phoenix* connectors
  • Detachable Neutrik powerCON* cable rated at 250 V / 32 A with variety of wall plugs selectable on order
  • Removable dust filter grille for increased air circulation and simple maintenance
  • Rugged 2U rackmount chassis including rear support brackets for ease of installation
  • 10-Year Warranty Program*
  • Designed and engineered in Sweden

Out of stock

Description

 

My default image

D SERIES D 200:4L

D 200:4L Combines 20000 W of Flexible Power with the Latest LAKE DSP, DANTE Digital Audio Networking and Advanced System Integrity Monitoring.

The D 200:4L is based on the same foundation of robust, high-power amplifier technologies as our renowned PLM Series – an amplifier platform with a proven record of reliability and sonic performance on the world’s most grueling concert tours and in
high-profile, large-scale installations.

With the D 200:4L, those same core technologies have been updated and refocused to provide the ultimate solution for the most demanding digitally networked installed sound applications – in stadia, arenas, theme parks, performing arts centers, racecourses and other large commercial sound installations.

In addition to legendary LAB GRUPPEN reliability and sonic excellence, the D Series incorporates newly refined outputs stage technologies along with installation-targeted hardware and software features that optimize amplifier system design and configuration. Together, these new technologies allow systems integrators to minimize both initial equipment costs and end users’ long-term energy consumption.

 

 

My default image

Rational Power Management (RPM)

At the core of the D Series platform is Rational Power Management (RPM), a proprietary LAB GRUPPEN technology that allows system designers and integrators unprecedented freedom to allocate the output power available on each channel for optimum performance with specific load conditions. RPM technology also enables the integrator to minimize initial equipment costs and reduce rack space requirement since with conventional installation amplifiers, it is often necessary to “over-specify” amplifiers to meet the maximum power demand on one channel, leaving excess power capacity wasted on the remaining channels. RPM reduces costly excess capacity by allowing re-allocation of output power capacity among the four channels – with each channel on the D 200:4L capable of delivering up to 5000 W power output, leaving any remaining available power to be allocated for less demanding loads.

 

 

 

My default image

CAFE for Green Credentials

The D 200:4L can be configured and monitored using the new CAFE (Configuring Amplifiers For the Environment) software suite. In addition to providing comprehensive system surveillance and configuration of RPM features, CAFE includes an innovative design aid – the Equipment Specification Predictor (ESP) – that provides tools for optimum specification of D Series units. ESP examines the system and load requirements and then supplies recommendations for the installation that include model and quantity of D Series units, heat generated, channel distribution, and current draw. The end result is accurate mains management and precise specification of cooling systems and UPS, when required.

MENU